Obiekt

Tytuł: The contact and immersion ultrasound methods compared using the ray tracing method

Autor:

Falhar, Martin ; Rehak, Jiri

Współtwórca:

Gaj, Miron. Redakcja ; Urbańczyk, Wacław. Redakcja

Opis:

Optica Applicata, Vol. 40, 2010, nr 1, s. 77-92

Abstrakt:

The goal of this article was to compare the contact and immersion ultrasound methods using simulated data. The pursued changes were interrelated with both the axial length of the eye and with partial biometry parameters. The results were compared with empirical data from real eye samples. The main analysing method was a modified algorithm for the ray tracing method created in the DELPHI programming environment (Borland Enterprise). The sample included 129 eyes (64% women and 36% men) of average age 73.65 (SD 9.33) scheduled for surgical removal of cataract. The average axial length was 23.12 mm (SD 1.31). The methods were compared using the simulated movement of the probe from central and coincident positions. We confirmed the tendency of the contact method to register more scattered beam which provides distorted biometric data from the periphery. This was verified by the real data analysis. The average axial length of the eye was 23.12 mm (SD 1.315), measured by the contact method and 23.26 mm (SD 1.298), measured by the immersion method. The difference between the methods was 0.145 mm. The most important changes occur in the vitreum depth which correlated with the total axial length (r = 0.89). The ray tracing method provided evidence of greater accuracy of the immersion method which was more sensitive to probe displacement and provided more accurate data. The axial length of the eye was longer according to the immersion method but this had only secondary influence on the accuracy of the method. Applanation of the cornea is the primary source of the contact method inaccuracy. The vitreum depth was the most influenced.

Wydawca:

Oficyna Wydawnicza Politechniki Wrocławskiej

Miejsce wydania:

Wrocław

Data wydania:

2010

Typ zasobu:

artykuł

Identyfikator zasobu:

oai:dbc.wroc.pl:58230

Źródło:

<sygn. PWr A3481II> ; kliknij tutaj, żeby przejść ; kliknij tutaj, żeby przejść

Język:

eng

Powiązania:

Optica Applicata ; Optica Applicata, Vol. 40, 2010 ; Optica Applicata, Vol. 40, 2010, nr 1 ; Politechnika Wrocławska. Wydział Podstawowych Problemów Techniki

Prawa:

Wszystkie prawa zastrzeżone (Copyright)

Prawa dostępu:

Dla wszystkich w zakresie dozwolonego użytku

Lokalizacja oryginału:

Politechnika Wrocławska

Tytuł publikacji grupowej:

Optica Applicata

Kolekcje, do których przypisany jest obiekt:

Data ostatniej modyfikacji:

22 sty 2019

Data dodania obiektu:

22 sty 2019

Liczba wyświetleń treści obiektu:

467

Wszystkie dostępne wersje tego obiektu:

https://dbc.wroc.pl/publication/96766

Wyświetl opis w formacie RDF:

RDF

Wyświetl opis w formacie OAI-PMH:

OAI-PMH

Podobne

×

Cytowanie

Styl cytowania:

Ta strona wykorzystuje pliki 'cookies'. Więcej informacji